Monday, April 21, 2014
 
  Home     About King     Products     Freight Policy & Sales Terms     Account Status     Contact King  
User: Guest Log In Now

ACSR Aluminum Conductor Steel Reinforced


New Search
Total Inventory Available

Call KINGWIRE

 
Code Word Description
Raven 1/0 ACSR 6/1 RAVEN BARE AL
 

Conductor

Size (AWG or kemit) Stranding ACSR (Al/Stl)
1/0 6/1
 
Diameter (inches)
Individual Wires Steel Core Complete
Cable OD
Alum Steel
.1327 .1327 .1327 .398
 
Weight (lbs/1000ft) Content %
Alum Steel Total Alum Steel
98.7 46.6 145.3 57.90 32.10
 
Rated Breaking Strength (lbs) Resistance
(OHMS/1000ft )
Current Rating
(Amps)
4,380 .149 DC@20°C
.217 AC@75°C
242
 
Standard Packages
Length (feet) Weight (lbs) Reel Size
1,515
12,180
6,090
4,060
220
1,770
885
590
Coil
NR 42.28
NR 36.22
NR 30.22
 
Applications
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
 
Construction
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B or C galvanizing; "aluminized" aluminum coated (AZ); or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.
 

Specifications
ACSR bare conductor meets or exceeds the following ASTM specifications:

B-230  Aluminum Wire, 1350-H19 for Electrical Purposes
B-231  Aluminum Conductors, Concentric-Lay-Stranded
B-232  Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341  Aluminum-Coated Steel Core Wire for aluminum Conductors, Steel Reinforced (ACSR/AZ)
 B-498  Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500  Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
 

1. Resistance is calculated using ASTM standard increments of stranding, and metal conductivity of 61.2% IACS for EC (1350), and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer construction.

2. Current ratings are based on 75°C conductor temperature, 25°C ambient, 2ft/s wind, 96/watts/sq. foot sun, .05 coefficients of emissivity and absorption.

To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.

The above data are approximate and subject to normal manufacturing tolerances.